• Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
  • Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
  • Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
  • Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
  • Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
  • Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box

Application: Power, Electronic, Instrument
Phase: Three
Core: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001, CCC
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
JLSZW-10KV
Usage
Three Phase Oil Immersed Transformer
Frequency Characteristics
High Frequency
Shape of Core
U
Brand
Cnkc
Defense
Safe and Convenient
Transport Package
Material Flow
Specification
10KV 5-1000A 10-80KA
Trademark
CNKC
Origin
China
Production Capacity
1000pieces/Year

Product Description


Product Description

This type of voltage and current combined transformer (measuring box) is used for AC 50Hz, rated voltage 20KV three-phase line, for voltage, current and energy measurement and relay protection. It is suitable for outdoor substations of urban power grids and rural power grids, and can also be used for various transformer power distribution stations in industrial and mining enterprises. The combined transformer is equipped with active and reactive watt-hour meters, which is called a high-voltage power metering box. This product can replace the oil-immersed combined transformer (metering box).

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box

Model Description

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering BoxJlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
Technical parameters and structure dimensions

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering BoxJlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box

Product features and scope of use

1. This product is assembled from dry single components, and there is no leakage problem, so it is oil-free.
2. The voltage and current are all cast with imported resin, which is like a building block structure, which is easy to replace, easy to maintain and save costs.
3. The product has high precision, and the current transformer can reach 0.2S level, which realizes wide load measurement.
4. The use of special materials enables the product to have high dynamic and thermal stability.
5. The voltage part can be equipped with a 220V auxiliary winding to provide power for switches, etc.
Applicable working conditions:
1. The height above sea level is not above 1000m. (Please indicate height above sea level if it is used in high land area).
2. Max.change of environment temperature doesn't exceed 5ºC to 40ºC. (If there is any requirement. Please indicate in the order).
3. Ordinary products can be used in the area with relative humidity not above 85%.
4. There is no gas, steam, chemical sedimentation, dust or dirt or other explosive and corrosive medium that seriously affect transformer at installation site. There is no serious vibration or bump. Either.

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box

Ordering instructions and usage matters

Ordering instructions:
1. Model, name and quantity of circuit breakers;
2. The rated voltage, rated current and rated short-circuit breaking current of the circuit breaker;
3. Circuit breaker shell material;
4. The operation mode of the operating mechanism (manual, electric, with remote control), the type and rating of the operating current;
5. Accuracy, transformation ratio, and quantity of current transformers; determine zero-sequence transformers, voltage transformers, etc.
6. The name and quantity of spare parts and spare parts;
7. If users have special requirements, please explain them when ordering.
Precautions:
1. When the primary current passes through the current transformer, the secondary winding is not allowed to open circuit, otherwise high voltage will be generated, which will affect the performance of the product.
2. The secondary winding of the voltage transformer is not allowed to be short-circuited. Otherwise it will burn the transformer.
3. The repeated power frequency withstand voltage test of the primary winding shall be performed at the specified test voltage.80% of the value.

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
Product details

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
Products real shot

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box

A corner of the production workshop

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box

Product packaging

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box

Product application case

Jlszw 10kv 5-1000A 10-80ka Outdoor Combined Metering Unit Combined Transformer Metering Box
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now