• Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer
  • Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer
  • Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer
  • Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer
  • Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer
  • Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Application: Instrument
Type: Voltage Transformer
Phase: Single
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer pictures & photos
Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer
US $399-799 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
JSZJK
Operation Condition
Outdoor
Usage
Protection
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Insulating Paper
Installation
Extension Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Photoelectric Type
Defense
Secure
Transport Package
Material Flow
Specification
10KV 5-1000A
Trademark
CNKC
Origin
China
Production Capacity
5000pieces/Year

Packaging & Delivery

Package Size
70.00cm * 21.00cm * 31.00cm
Package Gross Weight
60.000kg

Product Description

Product Description

JSZJK-10Q voltage transformer is a three-phase, indoor and dry type product, JSZK1-10 is Yo/Yo[connection JSZK1-10F is Yo/YoIYO[connection. The anti-resonance part is a single body. It is suitable for electric energy metering, voltage monitoring and relay protection in the rated frequency of 50Hz or 60HZ. The rated voltage is 6kV.

Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage TransformerModel DescriptionJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage TransformerJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Technical parameters and structure dimensions

Rated insulation 11.5/42/75KV
Rated frequency 50HZ
Ambient temperature -5ºC - +40ºC
The power factor of the load COSΦ=0.8 (lag);
Altitude is less than or equal to 1000m, which meets Class II pollution level;
Product performance meets the standard: GB1207-1997 (voltage transformer)Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage TransformerJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage TransformerJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage TransformerJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Product features and scope of use

1. JSZJK-10Q voltage transformer is an indoor epoxy resin full vacuum casting structure. Its surface creepage distance is greater than 25.m/kV
2. When the JSZK1-10 and JSZK1-10F voltage transformers are used in the system, each of them has four casting bodies, and the inner part is three voltage casting bodies, which are sleeved on the three-phase core column, and the anti-resonance part is installed in another port. On the iron core, during normal operation, the neutral point-to-ground voltage is zero volts, and the secondary output voltage of the anti-resonance part is zero volts, and one is short -circuited to ground. The secondary side (da-dn) of the anti-resonance part generates a voltage of 100V, which drives the relay to act, and the neutral point of the power supply is cut off. Harmonic elimination measures are adopted, so that the product does not need additional protection methods such as harmonic elimination or damping grounding, that is, it can be safely It can operate on the power grid and can operate in a single-phase grounded fault line for a long time.
environmental conditions:
1. The altitude does not exceed 1000m;
2. The ambient temperature is not higher than +40c, not lower than -5 ºC;
3. The relative humidity of the surrounding air is not more than 85% (20c);
4. There is no corrosive gas in the installation site

Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Ordering instructions and usage matters

Order plan:
1. Provide wiring scheme diagram number, purpose and single-line system diagram, rated voltage, rated current, etc.
2. Requirements for switchgear control, measurement and protection functions and other locking and automatic devices
3. When the switchgear is used in special environmental conditions, it should be explained in detail when ordering
4. When other or more accessories and spare parts are needed, the type and quantity should be proposed
Precautions:
1. Before the voltage transformer is put into operation, the test and inspection shall be carried out according to the items specified in the regulations. For example, measuring polarity, connection group, shaking insulation, nuclear phase sequence, etc.
2. The wiring of the voltage transformer should ensure its correctness. The primary winding should be connected in parallel with the circuit under test, and the secondary winding should be connected in parallel with the voltage coil of the connected measuring instrument, relay protection device or automatic device. At the same time, attention should be paid to the correctness of the polarity. .
3. The capacity of the load connected to the secondary side of the voltage transformer should be appropriate, and the load connected to the secondary side of the voltage transformer should not exceed its rated capacity, otherwise, the error of the transformer will increase, and it is difficult to achieve the correctness of the measurement.
4. No short circuit is allowed on the secondary side of the voltage transformer. Since the internal impedance of the voltage transformer is very small, if the secondary circuit is short-circuited, a large current will appear, which will damage the secondary equipment and even endanger personal safety. The voltage transformer can be equipped with a fuse on the secondary side to protect itself from being damaged by a short circuit on the secondary side. If possible, a fuse should also be installed on the primary side to protect the high -voltage power grid from endangering the safety of the primary system due to the failure of the high-voltage winding or lead of the transformer.
5. In order to ensure the safety of people when touching measuring instruments and relays, the secondary winding of the voltage transformer must be grounded at one point. Because after grounding, when the insulation between the primary and secondary windings is damaged, it can prevent the high voltage of the instrument and the relay from endangering personal safety.
6. Short circuit is absolutely not allowed on the secondary side of the voltage transformer

Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Product detailsJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Products real shotJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

A corner of the production workshop

Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage TransformerProduct packagingJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

Product application caseJszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer pictures & photos
Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer
US $399-799 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14001
Export Year
2023-12-21