• Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
  • Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
  • Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
  • Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
  • Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
  • Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Breaking Capacity: High Voltage Circuit Breakers
Operation: Energy-storage Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Structure: Ard
Samples:
US$ 400/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LW36
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Rated Frequency
50/60Hz
Rated Voltage
126kv
Rated Currrent
3150A
First Pole to Clear Factor
1.5
Rated Short Circuit Breaking Current
40ka
Rated Short Circuit Current
100ka
Rated Short Circuit Withstand Current
40ka
Rated Peak Withstand Current
100ka
Rated out of Step Current
10ka
Rated Short Circuit Duration
4s
Rated Line Charging Close Current
31.5A
Rated Operation Sequence
O-0.3s-Co-180s-Co35
Rated Sf6 Gas Pressure
0.6MPa
Mechanical Life
10000 Times
Quallity of Each Circuit Breaker
1700kg
Transport Package
Wooden Box Shipping
Specification
4000*650*5220mm
Trademark
CNKC
Origin
China
Production Capacity
1000PCS/Monthly

Product Description

Product Description
LW36-126/3150-40 type self-energy AC high voltage sulfur hexafluoride circuit breaker is an outdoor product, suitable for areas not exceeding 3000 meters above sea level, ambient temperature not lower than -40 degrees Celsius, and pollution level not higher than class IV In the power grid with AC 50Hz and maximum voltage of 145KV, it is used to cut off the rated current, fault current or conversion line to realize the control and protection of the power system, and can also be used as a tie circuit breaker.
This product uses SF6 gas as the arc extinguishing and insulating medium, adopts the most advanced self-energy arc extinguishing technology in the world, and is equipped with a new type of spring operating mechanism. It has the characteristics of long electrical life, low operating power, low noise and high reliability. It has simple structure, small size and long period of no maintenance. It is the most reliable product in high altitude area or 132KV power system, and can replace imported products of the same type.

Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Model Description
Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Product technical parameters and external dimensions

Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Product structure features 
1.Adopt self-extinguish principle, small operating energy, light mechanical impact;
2.Use spring mechanism, its performance is not relevant to temperature, stable performance;
3.Optimized interrupter structure and movement curve of contact, high reliability on breaking current;
4.Reignite and restrike cannot occur under breaking capacitive current;
5.Optimized pole and frame design with higher capability to endure earthquake;
6.High reliability, long average normal service time, low maintenance cost;
7.Convenient installation and configuration in field, it takes only one day or two days;
8.Low operating noise, suit for residential area


Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Environment condition

1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h.
2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M.
3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually.
4. Installation gradient not exceed 5.
5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components.
6. Any specific requirement, consult with manufactory.

Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
Product details
Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Products real shot

Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

A corner of the production workshop
Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Product packaging

Lw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing

Product application caseLw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic ReclosingLw36-126kv 3150A Outdoor Self-Energy AC High Voltage Sf6 Circuit Breaker Automatic Reclosing
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now