Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer

Product Details
Customization: Available
Application: Electronic, Instrument, Power System
Type: Current Transformer
Still deciding? Get samples of US$ 60/Set
Request Sample
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001
Export Year
2023-12-21
  • Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
  • Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
  • Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
  • Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
  • Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
  • Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
Find Similar Products

Basic Info.

Model NO.
LCZ-35
Phase
Single
Operation Condition
Outdoor
Usage
Protection, Measurement
Winding Form
Small Fixed Type
Insulating Medium
Porcelain Insulated
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Rated Insulation Level
40.5/95/185 Kv
Rated Frequency
50Hz or 60Hz
Installation Place
Indoors
Pollution Level
Level II Pollution
Rated Current
50A,75A,100A
Feature
Can Be Customized According to Users
Transport Package
Carton
Specification
400*915mm
Trademark
CNKC
Origin
China
Production Capacity
5000PCS/Monthly

Product Description

Product Description
LCZ-35 current transformer is a semi-closed insulation casting product,  suitable for power system with rated frequency of 50Hz or 60Hz and rated voltage of 35kV and below,  as electric energy measurement,  current measurement and relay protection. This product complies with IEC44-1 and GB1208 "Current Transformer".

Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer

Model Description
Lcz-35 50-1500A Indoor High Voltage Dry Current TransformerLcz-35 50-1500A Indoor High Voltage Dry Current Transformer

Technical parameters and structure dimensions
1. The rated secondary current, accuracy class combination,  rated output and dynamic and thermal stable current are shown in the table  
2. Rated insulation level:  40.5/95/185 Kv
3. The partial discharge level of the product meets the requirements of the GB1208 "Current Transformer" standard. 4. Pollution level:  the products in all working conditions meet the requirements of level II pollution.
5. Non-standard products can be  customized according to users.

Lcz-35 50-1500A Indoor High Voltage Dry Current TransformerLcz-35 50-1500A Indoor High Voltage Dry Current Transformer

Product features and Instruction for use
This type of current transformer is of epoxy resin casting semi-enclosed structure. The primary winding and the  secondary winding are first cast into one,  and then the iron core is inserted into the casting body. The product has excellent insulating properties and moisture  resistance. There are grounding bolts and nameplates and four mounting holes for installation on the bottom plate of the  product. normal use conditions:
Installation place: indoors.
Ambient temperature: the temperature is 40ºC;  the temperature is -5ºC;  the daily average temperature does not exceed 30ºC.
Atmospheric conditions:  There is no serious pollution in the atmosphere.  
Product Instructions:  
1) LCZ-35(Q) The wiring of the LCZ-35 current transformer current transformer should follow the series principle:  that is, the primary winding should be connected in series with the circuit under test,  and the secondary winding should be connected in series with all instrument loads
2) Select the appropriate change  according to the measured current, otherwise the error will increase. At the same time,  one end of the secondary side must be grounded to prevent the high voltage on the primary side from entering the  secondary low voltage side once the insulation is damaged,  causing personal and equipment accidents
3) The secondary side is absolutely not allowed to open circuit,  because once the circuit is open, the primary side current I1 will all become magnetizing current,  causing φm and E2 to increase sharply, resulting in excessive saturation magnetization of the iron core, serious heat generation and even burning of the coil;  , which increases the error. When the current transformer is working normally,  the secondary side is similar to a short circuit. If it is suddenly opened,  the excitation electromotive force will suddenly change from a small value to a large value,  and the magnetic flux in the iron core will show a severely saturated flat top. Therefore,  the secondary winding will induce a very high peak wave when the magnetic passes through zero,  and its value can reach thousands or even tens of thousands of volts,  which endangers the safety of the staff and the insulation performance of the instrument. In addition,  the open circuit of the secondary side makes the voltage of the second ary side reach several hundreds of volts,  which will cause an electric shock accident if touched. Therefore,  the secondary side of the current transformer is equipped with a short-circuit switch to prevent the secondary side from  being open. In the process of use, once the secondary side is open, the circuit load should be removed immediately,  and then the power outage should be processed. It can be reused after everything is disposed of.
4) In order to meet the  needs of measuring instruments, relay protection, circuit breaker failure judgment and fault filtering, etc.,  all circuits are installed in generators, transformers, outgoing lines, bus sectional circuit breakers,  bus circuit breakers,  bypass circuit breakers and other circuits. 2 to 8 current transformers with secondary windings.
5) The installation  site of the protective current transformer should be set as far as possible to eliminate the non-protection zone of the  main protection device. For example:  if there are two sets of current transformers, and the location allows,  they should be located on both sides of the circuit breaker,  so that the circuit breaker is in the cross protection range
6) In order to prevent the busbar failure caused by the  bushing flashover of the pillar-type current transformer,  the current transformer is usually arranged on the outgoing line or the transformer side of the circuit breaker.
7) In  order to reduce the damage caused by the internal fault of the generator,  the current transformer used for the automatic adjustment of the excitation device should be arranged on the outgoing  side of the stator winding of the generator. In order to facilitate analysis and find internal faults before the  generator is integrated into the system,  the current transformer used for measuring instruments should be installed on the neutral side of the generator.

Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
Product details
Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
Products real shot
Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer

A corner of the production workshop
Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer

Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
Product packaging
Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
Product application case
Lcz-35 50-1500A Indoor High Voltage Dry Current Transformer
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More