Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant

Product Details
Customization: Available
Material: Galvanized Steel
Usage: for Air Conditioner
Still deciding? Get samples of US$ 49.8/Piece
Request Sample
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001
Export Year
2023-12-21
  • Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
  • Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
  • Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
  • Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
  • Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
  • Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
Find Similar Products

Basic Info.

Model NO.
BT/CBF
Pressure
High Pressure
Certification
RoHS, UR, ISO, CE, CCC
Power
0.25-7.5
Blade Angle
30
Speed
Lowest:960
Speed/Min
Highest:2900
Number of Blades
4
Rated Voltage
380/220
Number of Model
3
Application
Ventilation and Cooling
Transport Package
Wooden Case
Trademark
CNKC
Origin
China
Production Capacity
5000/Monthly

Product Description

Product Description:
Explosion-proof axial flow fans are suitable for conveying flammable,  explosive and non-corrosive gases. The ambient temperature should not exceed 60 °C. They are widely used in general  factories, warehouses, offices,  and residences for ventilation or strong heating for heat dissipation. The air pipes are installed in series at  intervals to increase the pressure in the pipes,  and the motor can be used as a free fan after removing the motor. The explosion-proof axial flow fan adopts the simplest  structure of the fan directly connected with the motor and the impeller,  which changes the complex structure of the current coal mine extraction axial flow ventilation and all adopts belt drive  or long shaft drive, which is convenient for operation and maintenance.
The most obvious feature of the explosion-proof axial fan is that during the start-up and operation of the isolation  fan, the sparks generated by the motor terminals,  stator and rotor or other components do not come into contact with the outside flammable and explosive gases,  which may cause safety accidents.

Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
Model Description:
Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial PlantBt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial PlantBt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial PlantTechinical Parameters:

Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant

Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
Product Feature and Use Environment:
Features:
1. The explosion-proof fan has the same function as the ordinary fan. Explosion-proof refers to obtaining the  explosion-proof certification stipulated by the state. Explosion-proof fans must use explosion-proof motors.
2. The flow channel components (impeller, casing,  etc.) of the explosion-proof fan must be made of soft and hard materials. In general,  the rotating parts and the fixed parts should adopt a soft and a hard way to prevent the friction or collision between  the parts from generating sparks in the event of failure. Commonly used materials are 2a01 duralumin for impeller blades  and blade rivets, and galvanized steel or glass fiber reinforced plastic for the shell.
3. The performance indicators listed in the performance table of explosion-proof fans are all valid ranges. It is  divided into five performance points according to the air volume. The choice depends on the performance table. The error  of the total pressure value of the qualified products of the factory fire-fighting fan under the rated air volume shall  not exceed ±5%. The performance selection table is for performance under standard conditions and is not affected by  technical documentation and order requirements.
4. The bracket is welded by steel pipe and angle iron. The blade is made of hot rolled steel. After static balance  calibration, it runs smoothly, with low vibration and low noise.
5. The shell adopts epoxy anti-corrosion coating, and the motor adopts special anti-corrosion motor,  which is used to transport corrosive gas. Explosion-proof axial flow fans are used to transport flammable and explosive  gases. The impeller is made of aluminum alloy,  and no sparks are generated during operation. The motor adopts explosion-proof motor.
6. The mesh cover is made of φ5/mm steel wire rope spot welding, which is sturdy and beautiful.
7. The bracket adopts high-frequency welded pipe, which is convenient and stable to use.
Applicable environment:
1. Applicable to Zone 1 and Zone 2 of explosive gas environment;
2. Applicable to Class IIA and IIB explosive gas environments;
3. Applicable to environments with temperature group T1~T4;
4. Applicable to petroleum refining, storage, chemical industry , medical facilities and other explosive hazardous environments;
5. The product is mainly used for ventilation and cooling.
Fan installation instructions:
1. Before installation, check in detail whether the fan is damaged or deformed. If there is damage and deformation,  it can be installed after proper repair.
2. When installing, pay attention to check whether the inferior parts are loose,  and the gap between the blade and the air duct should be uniform and not collide.
3. The weight of the duct connecting the tuyere should not be borne by the duct of the fan,  and additional support should be added during installation.
4. A collector must be installed at the tuyere end of the fan, and a protective net must be installed.
5. The base of the fan must be naturally connected with the ground plane,  and the base must not be knocked forcibly connected to prevent the base from being deformed. During installation,  the base should be adjusted, shims should be added, and the horizontal position should be maintained,  and then the anchor bolts should be tightened.
6. After the installation is completed, the experiment must be carried out first,  and the official use is allowed only after the operation is normal.


Product Details:
Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
Products real shot:
Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
A corner of the workshop:
Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
Product packaging:
Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
Product application use:
Bt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial PlantBt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial PlantBt/Cbf 220/380V 0.18-7.5kw Explosion Proof Axial Flow Fan for Strong Smoke Exhaust and Ventilation in Industrial Plant
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More