• Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
  • Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
  • Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
  • Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
  • Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
  • Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

Application: Instrument
Type: Voltage Transformer
Phase: Single
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening pictures & photos
Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
US $399-699 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
LXK
Operation Condition
Outdoor
Usage
Protection
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Insulating Paper
Installation
Extension Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Photoelectric Type
Transport Package
Material Flow
Specification
10/35KV
Trademark
CNKC
Origin
China
Production Capacity
5000pieces/Year

Packaging & Delivery

Package Size
17.00cm * 12.00cm * 17.00cm
Package Gross Weight
5.000kg

Product Description

Product Description

Zero sequence current transformer is suitable for use with DD-11/60 or DD-1/60 type relay and signal device in small grounding current system with rated frequency 50/60Hz and rated voltage 35kV and below, for residual (zero sequence) current detection and grounding protection, and at the same time make device components move, to achieve protection and monitoring.
LXK series residual (zero sequence) current transformers are cable type resin casting insulation indoor products, this series of zero sequence current transformers are open and close, epoxy resin casting structure, installation can be divided into two parts, and then merged into one, easy to install, Transformer inner diameter is φ 80, φ100, φ120, φ140, φ150, φ160, φ180, φ200, φ240, φ260, φ300 several specifications

Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer OpeningModel DescriptionLxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer OpeningTechnical parameters and structure dimensionsLxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer OpeningLxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer OpeningLxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

Product features and scope of use

1. The core of the current transformer has adoped amorphous alloy, it has high magnetic permeability, low saturation induction density and good stability.
2. High quality silicon steel sheet is taken to be the core of windings protection, which ensures the high accuracy limit factor.
3. The circular ring core and secondary windings are poured by high quality expoxies resin or polyurethane or silicon rubber in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance. the cable can cross the current transformer through its internal poles quickly and uniformly.

Ambient temperature:-10ºC-+40ºC
Relative humidity:The average humidity of a day should be no more than 95%. The average humidity of a month should be no more than 90%.
Earthquake intensity: not exceed 8 degrees.
Saturated vapor pressure the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more
Than1.8Kpa;
The height above sea level:≤1000 m (Except special requirements)
It should be installed in the places without fire, explosion, serious filth, and chemical erosion and violent vibration.

Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer OpeningProduct detailsLxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer OpeningLxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

Products real shotLxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

A corner of the production workshop

Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer OpeningLxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

Product packaging

Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening

Product application case

Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening pictures & photos
Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
US $399-699 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14001
Export Year
2023-12-21