• Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
  • Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
  • Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
  • Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
  • Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
  • Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Breaking Capacity: High Voltage Circuit Breakers
Operation: Energy-storage Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Structure: Ard
Samples:
US$ 400/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LW8
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Rated Frequency
50/60Hz
Rated Voltage
40.5kv
Rated Currrent
1600/2000A
Rated Short Circuit Dropout Current
25-31.5ka
Rated Insulation Level
95-185kv
Rated Short Circuit Close Current
63-80ka
Rated Short Circuit Duration
4s
Rated Short Time Withstand Current
25-31.5ka
Rated Operation Sequence
O-0.3s-Co-180s-Co
Rated Sf6 Gas Pressure
0.5map
Mechanical Life
3000 Times
Quallity of Each Circuit Breaker
1400kg
Weight of Sf6 Gas
8kg
Voltage of Closing and Opening Coils
AC220-380V/ DC48/110/220V
Voltage of Energy Storage Motor
AC220-380V /DC110-220V
Transport Package
Wooden Box Shipping
Specification
2740*1280*2600mm/1750*500*3774mm
Trademark
CNKC
Origin
China
Production Capacity
1000PCS/Monthly

Product Description

Product Description
LW8-40.5 outdoor SF6 circuit breaker is an outdoor device used in AC 50HZ three-phase 40.5KV power system, to act as the protecting and control unit for grid equipments and industrial mining enterprises equipments. It is applicable to locations that need frequent operating in rated current or under repeatedly on/off short circuit current. Containing the current transformer for measurement and protection.
It can directly replace SW2-35 less oil circuit breaker and various types of oil circuit breaker with transition bracket, also be used as a tie breaker and switching capacitor group situations with CT14 type spring mechanism.

Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Model Description
Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Product technical parameters and external dimensions

Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto RecloseLw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
Product type selection
Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Product structure features 
a. The circuit breaker is outdoor small ceramic column structure, which equipped with CT14 spring operation mechanism; mechanism and main part connected with simple installation. It has features of convenient adjustment, reliable operation, suitable for frequent operation; mechanism service life more than 3000 times;
b. Adopt air-compression arc-extinguishing structure, with strong breaking capacity, 40kA total breaking times up to 12, which is the highest in China:
c. Reliable sealing performance. Adopt import seal; dynamic seal adopts "V" type sealing ring with spring pressure compensation structure; the transformer secondary wiring board matched by cooperative enterprises, to ensure the annual leakage rate less than 1%,
d. Inner current transformer adopts micro crystallizing alloy high magnetic materials, with accurate class up to grade 0. 2 or grade 0.2S. According to users' needs, it can be matched with 12 transformers, to meet the load line of 50 km without restrike.


Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Environment condition

1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h.
2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M.
3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually.
4. Installation gradient not exceed 5.
5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components.
6. Any specific requirement, consult with manufactory.

Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
Product details
Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto RecloseLw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Products real shot

Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

A corner of the production workshop
Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Product packaging

Lw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose

Product application caseLw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto RecloseLw8-40.5kv 2000A Outdoor High Voltage Three-Phase AC Sf6 Circuit Breaker Auto Reclose
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now