Type: High-voltage
Structure: Double-column Disconnector
Installation: Indoor High-voltage
Operation: Electric
Grounding Mode: Grounding
Movement Mode: Plug-in Type
Samples:
US$ 150/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FZRN25
Number of Poles
Unipolar
Grounding
Single Ground
Series
Two
Run
Plug-In
Switching Mode
Double-Throw Type
Common Model
Gw4
Structure of Operating
Electric
Certification
ISO, CE, ISO9001
Brand
Cnkc
Rated Voltage
12kv
Rated Frequency
50Hz
Rated Contact Pressure
No More Than 650
Rated Current
125/630A
Opening Time of Disconnecting Time
More Than 2
Jump Time of Contact Closing
No More Than 5
Transport Package
Woodencase
Specification
1040
Trademark
CNKC
Origin
China

Product Description

Product Descrption
FZRN25-12D/T630-20 type indoor AC HV load switch is an indoor device of three-phase AC 50Hz and rated voltage 12K.It is  applied to the sites of distribution substation of industrial and mining enterprises and substation etc,  used for protecting and conteolling electric facilities,on and off load current,  closed lop current,zero load transformer and cable charging current.
Equipped with manual and electromotive actuating mechanism,it is easy to realize the three remote control requirements  for electric system.
FZRN25-12D/125-31.5 type indoor AV HV load switch -fuse combined electrical equipment is an indoor device of three-phase  AC 50Hz and rated voltage 12KV.It is applied to the sites of distribution substation of industrial and mining  entrtpriese and substation etc,used for load control and short circuit protection.The equipped ground switch can bear  short circuit current.The manual and electromotive actuating mechanism for electric system.
FZN25-12D and FZRN25-12D type load switch and combined electrical equipment are applied to the urban areas distribution  substation substation of three-phase ring net or rerminal supply and industrial electric devices,used for load control  and short circuit protection.As the combined electrical equipments bring more reliable and economic protection functions  to transformer etc electriacal devices,so it is especially applied to ring net,duble radiation supply unit and box type  substationFZRN25-12D/T630-20 type indoor AC HV load switch is an indoor device of three-phase AC 50Hz and rated voltage  12K.It is applied to the sites of distribution substation of industrial and mining enterprises and substation etc,  used for protecting and conteolling electric facilities,on and off load current,  closed lop current,zero load transformer and cable charging current.
Equipped with manual and electromotive actuating mechanism,it is easy to realize the three remote control requirements  for electric system.
FZRN25-12D/125-31.5 type indoor AV HV load switch -fuse combined electrical equipment is an indoor device of three-phase  AC 50Hz and rated voltage 12KV.It is applied to the sites of distribution substation of industrial and mining  entrtpriese and substation etc,used for load control and short circuit protection.The equipped ground switch can bear  short circuit current.The manual and electromotive actuating mechanism for electric system.
FZN25-12D and FZRN25-12D type load switch and combined electrical equipment are applied to the urban areas distribution  substation substation of three-phase ring net or rerminal supply and industrial electric devices,used for load control  and short circuit protection.As the combined electrical equipments bring more reliable and economic protection functions  to transformer etc electriacal devices,so it is especially applied to ring net,duble radiation supply unit and box type  substation.
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch

Model Dscription
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load SwitchFzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch
Technical parameters and structure dimensions
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load SwitchFzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load SwitchFzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch
Product Structural features and working principle

1. The product uses vacuum interrupter. Its performance is stable and  reliable, with long electrical life, high breaking capability,  strong making/breaking ability and easy to be operation and maintenance.
2. It combines switch body and operating  mechanism, which integrates disconnector,  load break switch and earthing switch. It is compact and with small volume.
3. Tandem arrangement of direct-acting  isolating fracture and vacuum interrupter, high dynamic and thermal stable current;  it can be operated at one time due to unique linkage operating procedures.
4. Structure of cone fixed contact,  insulation cover and shutter can separate busbar and load break switch unit completely.
5. Vacuum load break switch,  earthing switch, shutter, switchgear door are in accordance with "5 prevention" mechanical interlock,  which can prevent misoperation and is safe and reliable.
6. Charged energy by spring operating mechanism,  can closing and opening by electrical and by manual.
7. Operating voltage of closing and opening can be DC and AC.
8.  The normal type is operated by left and right side operating mechanism,  but can with front operating mechanism as user's requirement.
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch

Environment condition
Ambient temperature:-10ºC-+40ºC
Relative humidity:The average humidity of a day should be no more  than 95%.
The average humidity of a month should be no more than 90%.
Earthquake intensity:  not exceed 8 degrees.
Saturated vapor pressure the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than1.8Kpa;
The average pressure of a month should be no more than1.8 kpa;
The height above sea level:≤1000 m (Except special requirements) It should be installed in the places without fire,  explosion, serious filth, and chemical erosion and violent vibration.
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch
Product Deatils
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load SwitchFzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch
Products real shot
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch
A coner of the production workshop
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch
Product Packaging
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch
Product allpcation use
Fzrn25-12D 12kv 630A Indoor High-Voltage Vacuum Load Switch
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now