Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector

Product Details
Customization: Available
Certification: ISO
Color: Dark Red
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001
Export Year
2023-12-21
  • Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector
  • Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector
  • Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector
  • Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector
  • Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector
  • Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector
Find Similar Products

Basic Info.

Model NO.
KW(JJC)
Surface Treatment
No
Usage
Electrical Appliance
Material
Aluminum Alloy
Type
H Type
Defense
Durable and Practical
Install
Quick and Convenient
Transport Package
Material Flow
Specification
1-20KV 0.75-400mm²
Trademark
CNKC
Origin
China
Production Capacity
5000pieces/Year

Packaging & Delivery

Package Size
50.00cm * 40.00cm * 30.00cm
Package Gross Weight
20.000kg

Product Description

Product Description

The insulation puncture clamp (connector) is mainly composed of an insulation shell, a puncture blade, a waterproof rubber pad, and a torque bolt. When making a cable branch connection, insert the branch cable into the branch cap and determine the branch position of the main line, then use a socket wrench to tighten the torque nut on the clamp. With the tightening of the torque nut, the upper and lower parts of the clamp have hidden insulators with piercing blades At the same time, the arc-shaped sealing rubber pad wrapped around the piercing blade is gradually clinging to the cable insulation layer, and the piercing blade also begins to pierce the cable insulation layer and metal conductor. When the sealing degree of the sealing rubber pad and insulating grease and the contact between the puncture blade and the metal body reach the best effect, the torque nut will automatically fall off, at this time, the installation is completed and the contact point sealing and electrical effect reach the best.
Insulation piercing clamps can be divided into 1KV, 10KV, and 20KV insulation piercing clamps according to voltage classification.
According to the functional classification, it can be divided into ordinary insulation piercing wire clips, electrical inspection grounding insulation piercing wire clips, lightning protection and arc proof insulation piercing wire clips, and fireproof insulation piercing wire clips

Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector

Technical parameters

Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable ConnectorKw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable ConnectorKw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable ConnectorKw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable ConnectorKw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable ConnectorKw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector

 

Product features and advantage

Structural features:
1. Puncture structure, simple installation, no need to peel the insulated wire;
2. Torque nut, constant puncture pressure, ensure good electrical connection without damaging the wire,
3. Self sealing structure, moisture-proof, water-proof and anti-corrosion, extending the service life of insulated conductors and clamps
4. Special contact blade is used for copper (aluminum) butt joint and copper aluminum transition
5. The electrical contact resistance is small, and it is less than 1.1 times of the resistance of equal length branch conductor, meeting the DL/T765.1-2001 standard
6. Special insulating shell, anti light and environmental aging, dielectric strength>12KV
7. Curved surface design, applicable to the connection of the same (reducing) diameter conductor, with a wide connection range (0.75mm2-400mm2)
Product advantages:
1. Simple installation: cable branch can be made without stripping the insulation skin of the cable, and the joint is completely insulated. It is not necessary to cut off the main cable, and branches can be made at any position of the cable. The installation is simple and reliable. It can be installed with electricity only by using a socket wrench.
2. Safety in use: the connector is resistant to twisting, shockproof, waterproof, flame retardant, and electrochemical corrosion aging, requiring no maintenance. It has been successfully used for more than 30 years.
3. Cost saving: the installation space is very small, saving the cable tray and civil engineering costs. For application in buildings, there is no need for terminal box, distribution box, cable return, and cable investment. The cost of cable+piercing clamp is lower than that of other power supply systems, which is only about 40% of the plug-in bus and about 60% of the prefabricated branch cable.

Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector

Product installation

1. Adjust the nut of the piercing clamp to the proper position, and insert the branch wire into the branch wire cap completely.
2. Insert the main line. If the main line has two layers of insulation, a certain length of outer insulation must be stripped at the connection position.
3. Put the main/branch line in a proper position and keep them parallel. First, tighten the nut by hand to fix the clamp.
4. Tighten the nut evenly with a socket wrench of the corresponding size until the top breaks off and the installation is complete.
Installation of the double-screw insulation piercing clamp:
1. Unscrew the clamp first and snap the main wire into the main wire groove. Do not jam the main wire and the knife ruler crookedly. Pay attention to whether the wire diameter range corresponds to this wire clip.
2. Put the branch line into the branch line slot. The precautions are the same as above.
3. Tighten with a socket wrench. Open-end wrenches are disabled.
4. Note that the two nuts should be screwed down synchronously in sequence.
5. When tightened to a certain strength, the constant torque nut is twisted off. The installation is complete.

Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable ConnectorKw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable ConnectorKw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector

Product details

Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector
Products real shotKw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector

 

A corner of the production workshop

Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector
Product packaging

Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector

Product application case
Kw (JJC) Series 1-20kv 0.75-400mm² Insulated Puncture Type Cable Connector

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More