• Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
  • Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
  • Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
  • Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
  • Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
  • Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting

Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting

Technics: Injection Molding
Standard: GB
Usage: Substation Fittings, Line Fittings
Type: Link Fittings
Structural Features: Aluminum Alloy Material
Wire: Not Easy to CREE
Samples:
US$ 2.0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
TL
Parts
Not Be Dropped
Bolt Quality
1-3
Features
Light Weight
Transport Package
Paper Box
Specification
120*150*60mm
Trademark
CNKC
Origin
China
Production Capacity
10000 Pices/Monthly

Product Description

Product Description
T-clamp refers to the hardware used to connect the conductor with the branch line to transfer electrical load. High voltage transmission line is an important part of power grid, which connects substations and transmits power. In the design of transmission lines, we can see the connection mode of line T-connection. T-connection lines are two lines with different spatial levels connected by short circuit at the intersection of the same voltage level. Substation A supplies power to substations B and C at the same time. The advantages are that investment is reduced and a substation bay is used less. This way of connecting another line from the main line is vividly called "T" connection mode, This outgoing point is called "T contact".
T-type clamp is mainly used for overhead circuit lines or substations, which leads down current branches on the main bus in a "T" mode. There are two types: bolt type and compression type. For small section conductors, the so-called T-type connection can also be used with parallel groove clamps or clamped elliptical splicing tubes.
TL series single conductor T-clamp is a kind of T-clamp used to connect branch conductor to the trunk conductor, including: T-shaped substrate, with trunk groove in the transverse part, with wire holes in the longitudinal part, metal linings are set on the inner wall of trunk groove and branch hole, and the two metal linings are connected as a whole, and the upper surface of the longitudinal part of the substrate is threaded with branch conductor compression screws; Trunk slot cover is inserted with trunk slot, and its upper surface is screwed with dry conductor compression screw; The T-shaped upper cover is buckled with the T-shaped base. When connecting, only the simple work of fastening screws is needed, which saves time and labor; The branch wire and the dry wire are in close contact with the metal lining through the compression screw, and the contact area is large, so the connection is safe and reliable.

Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
Technical parameters

Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting

Product features and Installation matters
Features:
a. The clip body is made of high-strength aluminum steel material.
b. The appearance is smooth and the service life is long.
c. Easy to install and use.
d. There is no hysteresis loss, and it is a low-carbon, energy-saving certified product.


Installation matters:

1. Clean one end of the crimped wire for about 1m and apply conductive grease.
2. Put the cleaned aluminum tube (outer diameter D) into the wire end and pull it 1m away from the wire end. 3. Use a vernier caliper or a tape measure to measure the size l 2 of the front end tube of the steel anchor, measure the length of the steel core to be stripped from the end O of the wire ON= l 2 + Δl mm (Δl is 15mm), make a mark, and tie it at a distance of 20mm from the mark Take the newly tied wire P. 4. Open a section of aluminum strand at the end O, and fasten the exposed steel core end with a binding wire. Then use a cutter (or aluminum wire stripper) to cut the outer and middle aluminum strands at the mark N. When cutting the inner aluminum strands, only cut to 3/4 of the diameter of each strand, and then break the aluminum strands one by one. When stripping the aluminum wire, it is strictly forbidden to bruise the steel core. )
5. Crimp the steel anchor
A. Select the steel pipe die "Cd#" that is consistent with the outer diameter d of the steel anchor. The installation instructions for the NY tension clamp in the substation should verify that the diagonal angle of the hexagonal die is dmm;
B. Press the steel After the core is cleaned, rotate and insert it into the bottom of the steel anchor along the stranding direction of the steel core, and the
end of the steel anchor exposes the steel core with a length of about 15mm; At this time, the wires on both sides should be
kept horizontal with the steel anchor, and consistent with the axis of the hydraulic press, so as to reduce the possible bending of the pipe after being compressed.
D. Crimp the front end pipe of the steel anchor. The direction of crimping is from the groove of the pipe to the pipe mouth. When applying pressure, the two adjacent molds
should overlap at least 5-10mm. After compression into a regular hexagon, the distance S between the opposite sides of the regular hexagon should be verified. The allowable value of S is: S=(0.866*0.993d)+0.2. After molding, use a standard caliper to check the size of the opposite side distance after pressing. (Note: The actual pressure of the hydraulic pump should not be lower than 80Mp, and when the pressure reaches the specified value, it should be maintained for 3-5s). Continue hydraulic operation only after the standard is met.
Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
Product details
Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting

Products real shot

Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
 

A corner of the production workshopTl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting

 
Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting

Product packagingTl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power FittingProduct application case

Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting


Tl 11-630mm² 7.5-34.5mm T-Connectors for Single Conductor of Bolt Type Electric Power Fitting
 
 