• Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
  • Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
  • Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
  • Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
  • Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer

Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer

Application: Instrument, Power System
Phase: Single
Core: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001-2000, ISO9001
Samples:
US$ 61/Set 1 Set(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
JSZWK-10
Usage
Single-phase Transformer, Power Transformer
Frequency Characteristics
High Frequency
Shape of Core
U
Brand
CHINT
Rated Frequency
50Hz
Rated Voltage
3,6,10kv
Thermal Limiting Output
1200va
Rated Insulation Level
40.5/95/200
Max Output
1500va
Transport Package
Wooden Case
Trademark
CNKC
Origin
China
Production Capacity
5000/Monthly

Product Description

Product Description
JSZWK-10 anti-vibration three-phase voltage transformer is mainly insulated by epoxy resin and special insulating  materials. It is equipped with a protective iron box and a porcelain sleeve,  which improves the moisture-proof performance and electrical insulation performance. This product is not afraid of  frequency division, high frequency, It will be burnt due to overvoltage,  and it can run in the case of single-phase grounding of the line for a long time without over-temperature concerns. At  the same time, the protection winding generates a voltage of 100V to drive the relay to work.
This type of voltage transformer is a new type of voltage transformer developed and developed after the three-phase  five-column voltage transformer to eliminate the public nuisance of ferromagnetic resonance and a large number of burnt  out of the transformer due to the grounding of the power system to different degrees.
Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer

Model Description
Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
Techinical parameters and Structure dimensions

Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined TransformerJszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
Product features and scope of use
The high voltage is converted into a standard secondary voltage of 100V or lower according to a proportional  relationship, which is used for protection, metering and instrumentation devices. At the same time,  the use of voltage transformers can isolate high voltages from electrical workers. Although the voltage transformer is  also a device that works according to the principle of electromagnetic induction,  its electromagnetic structure relationship is exactly opposite to that of the current transformer. The secondary circuit  of the voltage transformer is a high-impedance circuit,  and the magnitude of the secondary current is determined by the impedance of the circuit. When the secondary load  impedance decreases, the secondary current increases,  so that the primary current automatically increases a component to satisfy the electromagnetic balance relationship  between the primary and secondary sides. It can be said that the voltage transformer is a special transformer with  limited structure and use form. Simply put, it is the "detection element".
Use environment:  
1. Installation location: outdoor;  
2. Ambient temperature: -25ºC ~ +60ºC;
3. Altitude: the altitude of the installation site should not exceed 2000 meters;  
4. Relative humidity: the daily average is not more than 95%, the monthly average is not more than 90%;  
5. The wind pressure does not exceed 700Pa (equivalent to a wind speed of 34m/s);  
6. Pollution level: 3

Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
Ordering notice
1. Provide wiring scheme diagram, application and system diagram, rated voltage, rated current, etc.
2. Requirements for control, measurement and protection functions and other locking and automatic devices.
3. When the transformer is used in special environmental conditions, it should be explained in detail when ordering.
4. When other or more accessories and spare parts are needed, the type and quantity should be proposed.

Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
Product details

Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
Product real shot
Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
A coner of the production workshop

Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
Product packaging
Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
Product application use
Jszwk-10kv Outdoor Anti-Resonance Voltage Transformer Combined Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now