Application: Instrument, Power System
Phase: Single
Core: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001-2000, ISO9001
Samples:
US$ 61/Set 1 Set(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
JDZ9-35
Usage
Single-phase Transformer, Power Transformer
Frequency Characteristics
High Frequency
Shape of Core
U
Brand
CHINT
Rated Frequency
50Hz
Rated Voltage
35kv(40.5kv)
Thermal Limiting Output
1200va
Rated Insulation Level
40.5/95/200
Max Output
800va
Transport Package
Wooden Case
Trademark
CNKC
Origin
China
Production Capacity
5000/Monthly

Product Description

Product Description
JDZ9-35 series of indoor voltage transformer, which is the epoxy resin casting,  fully enclosed post structure. It's rated frequency 50Hz or 60Hz, rated voltage of power system up to 35kV(40.5kV), for measuring current,  electric energy and relay protection. The iron core and windings of the voltage current are casting together. The types  of JDZ9-35 arid JDZF9-35 are single-phase transformers connected between phases to phase. The JDZF9-35 has two secondary  windings and it has a energy measuring from voltage monitoring and relay protecting separately,  which is made of cold rolled silicon steel sheet. This voltage transformer conforms to IEC60044-2 and GB1207-2006  standard.
Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer

Model Description
Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage TransformerJdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
Techinical parameters and Structure dimensions

Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage TransformerJdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage TransformerJdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
Product features and scope of use
This series of voltage transformers is of epoxy resin casting pillar type fully enclosed structure. The iron core and  the winding are cast into one body,  and there is a mounting plate at the bottom. JDZ9-35 is single-phase and connected to the opposite phase. That is,  the energy measurement and voltage monitoring are separated. JDZX9-35 is single-phase, connected to the ground,  the primary A terminal is connected to the phase line,  and the N terminal is grounded. JDZXF9-35 has three secondary windings, that is, the energy measurement,  voltage monitoring and relay protection are separated. . JDZX9-35G is a fully insulated structure,  the primary A terminal is connected to the phase line,  and the N terminal is grounded. JDZXF9-35G has three secondary windings, that is, energy measurement,  voltage monitoring and relay protection are separated.
It is resistant to dirt and moisture,  and is also suitable for use in tropical areas. The transformer does not require special maintenance,  but only needs to remove the surface dirt regularly. Since the transformer is fully enclosed and cast insulation,  it is small in size and light in weight,  suitable for installation in any position and direction. . A terminal box is installed at the secondary outlet terminal.  There are three outlet terminal holes on the box,  and the secondary wires can be drawn from different directions. The wiring is convenient, safe and reliable,  and can realize anti-theft measures.

Ambient temperature:-10ºC-+40ºC
Relative humidity:The average humidity of a day should be no more than 95%. The average humidity of a month should be no  more than 90%.
Earthquake intensity: not exceed 8 degrees.
Saturated vapor pressure the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more
Than1.8 Kpa.
The height above sea level:≤1000 m (Except special requirements)
It should be installed in the places without fire, explosion, serious filth, and chemical erosion and violent vibration.

Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
Ordering notice
1. Provide wiring scheme diagram, application and system diagram, rated voltage, rated current, etc.
2. Requirements for control, measurement and protection functions and other locking and automatic devices.
3. When the transformer is used in special environmental conditions, it should be explained in detail when ordering.
4. When other or more accessories and spare parts are needed, the type and quantity should be proposed.

Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
Product details

Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage TransformerJdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
Product real shot
Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
A coner of the production workshop

Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
Product packaging
Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
Product application use
Jdz9-35 60/250/ 500va Indoor Pillar Type Single-Phase Dry-Type Voltage Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now