• Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge
  • Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge
  • Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge
  • Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge
  • Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge
  • Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: High-Speed Circuit Breaker
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge pictures & photos
Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge
US $99-299 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
HY5WBG
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
ACB
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CCC
Defense
Secure
Transport Package
Material Flow
Specification
10kv
Trademark
CNKC
Origin
China
Production Capacity
5000pieces/Year

Packaging & Delivery

Package Size
20.00cm * 8.00cm * 25.00cm
Package Gross Weight
15.000kg

Product Description

Product Description

At present, the process of overhead insulation below 10KV in urban and rural areas is very fast. However, in the distribution transformer area on the pole, there are many connection parts such as switches, arresters, connecting clips, and pillars, which bring many operating fault points, poor insulation and safety protection conditions, complicated installation and maintenance. There are a series of problems such as difficulty, high cost, and poor live working conditions. In order to deal with the above problems, it is necessary to transform some equipment and line connection methods of the distribution transformer system on the pole, so that it can achieve the purpose of simplifying the device and further increasing the operation safety. HY5WBG type synthetic jacketed zinc oxide arrester device has the function of strut, arrester, puncture and electrification, and grounding function. It has a multi-purpose structure. The use of this device can also reduce one arrester cross-arm (because of the use of the originally required pillar cross-arm), can reduce the three insulators used for fixing the sag, that is, seven peeling points, reduce construction time, and reduce six If the fault point is located, the purpose of simplifying the line device, further increasing the safety and reliability of operation, and making the line more concise and beautiful. This device integrates a variety of functions, and insulates the insulation that originally required seven peeling points into one.The design of the shield is reasonable and can truly achieve the whole insulation, creating favorable conditions for safety and live operation

Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Model DescriptionHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap DischargeProduct technical parameters Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap DischargeHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Product Structural features and scope of use

1. The core body and jacket of the arrester are molded into a compact whole without a cavity, which eliminates the moisture absorption caused by breathing and fundamentally eliminates the accident caused by the damping of the arrester chip.
2. The inside of the arrester adopts a special strengthening structure, which makes it have good mechanical properties and can also be used as an insulator
3. The synthetic jacket of the arrester is made of silicone rubber material, which makes it have strong anti-pollution performance and good explosion-proof performance. In addition, light weight and long service life
4. The arresters are designed and produced according to the class III heavy pollution resistance. The minimum creepage ratio of the insulating jacket is 25mm/KV, and the creepage distance is 320mm.
5. The overall structure of the arrester is optimized and has a combined function.
a. It has both grounding stems, which can meet the needs of electricity inspection and grounding, and can simplify the tower installation
b. The special reinforcement structure makes it have good mechanical properties and can double as a pillar insulator
c. The connection terminal block can segment the cable fault, reduce the power failure range, and has the function of breaking the knife switch
d. The use of full insulation design can effectively avoid the occurrence of accidents such as external force damage
6. The arrester device has the function of supporting pillars, connecting terminal busbar wiring, and electrical inspection and grounding. The connecting terminal busbar can segment cable faults, reduce the scope of power outages, and has the function of segmenting a knife switch.Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap DischargeHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap DischargeHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

 

Product Specifications and Production ProcessHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap DischargeHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap DischargeHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Product implementation standards and user notices

The production standard of the product is GB11032-2000 (eqv IEC60099-4:1991) "AC No-gap Metal Oxide Surge Arrester", JB/8952-2005 "Composite Jacket No-gap Metal Oxide Surge Arrester for AC System"
1. The arrester should be stored in a clean and dry room before installation and use. Must not be corroded by corrosive gases or liquids.
2. Before the arrester is put into operation, a preventive test should be carried out. After being put into operation, it should also be regularly (10KV and below arrester once every 5 years, 35KV and above arrester once every 2 years)
Do the following test and compare with the data before operation with reference to the attached table:
a. Measure the insulation resistance of the arrester
b. Measure the DC 1mA voltage of the arrester
c. Measure the leakage current of 0.75 times DC 1mAHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Product detailsHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap DischargeHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Products real shotHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

A corner of the production workshopHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap DischargeHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Product packaging

Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Product application caseHy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge pictures & photos
Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge
US $99-299 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14001
Export Year
2023-12-21