• Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
  • Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
  • Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
  • Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
  • Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
  • Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Vcb
Samples:
US$ 300/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
ZW7
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Rated Frequency
50/60Hz
Rated Voltage
40.5kv
Rated Currrent
1250/1600/2000A
Rated Short Circuit Breaking Current
25-31.5ka
Rated Operation Sequence
O-0.3s-Co-180s-Co
Mechanical Life
10000 Times
Rated Peak Withstand Current
63-80ka
Rated Short Time Withstand Current
25-31.5ka
Rated Short Circuit Closing Current
63-80ka
Rated Current Breaking Time
10000 Times
Opening Time
60ms and Below
Closing Time
150s and Below
Weight
800kg
Transport Package
Wooden Box Shipping
Specification
2465*500*2400mm
Trademark
CNKC
Origin
China
Production Capacity
2000PCS/Monthly

Product Description

Product Description
ZW7-40.5 Type vacuum circuit breaker is mainly used for outdoor 35kV power transmission system control and protection also applies to urban and rural power distribution networks and industrial and mining enterprises in the normal operation and short circuit protection purposes. The overall structure of the insulator pillar product type; built vacuum interrupter type on the vase, porcelain vase for the next pillar vase. For frequent operation place. And has good sealing, anti-aging, high pressure, no burning, no explosion, long life, convenient installation and maintenance features.

Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Model Description

Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Product technical parameters and external dimensions

Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Product structure features 
1. Vacuum arc extinguishing, strong breaking capacity, long electrical life and 10,000 mechanical life;
2. Simple structure, maintenance-free, long maintenance period;
3. Good insulation performance and strong anti-pollution ability;
4. It can be equipped with spring or electromagnetic operating mechanism, with reliable mechanical performance and frequent operation; no fire and explosion hazard;
5. Built-in current transformer, the lecturer's precision reaches 0.2, which can realize three-phase interactive protection;
6. With condensation controller, it can keep the circuit breaker running reliably under certain temperature and humidity.


Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Environment condition

1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h.
2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M.
3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually.
4. Installation gradient not exceed 5.
5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components.
6. Any specific requirement, consult with manufactory.

Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
Product details
Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Products real shot

Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

A corner of the production workshop
Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Product packaging

Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser

Product application caseZw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto RecloserZw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker Auto Recloser
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now